Summary

Use a structured oxygenation/ventilation escalation: start simple, reassess quickly, choose HFNC vs NIV by physiology, and intubate early when failure criteria appear.

Details

WHEN TO USE

  • Hypoxemia, hypercapnia, increased work of breathing.

ESCALATION LADDER

  • Nasal cannula/simple mask → nonrebreather if needed.
  • HFNC for hypoxemia with high flow needs.
  • NIV (BiPAP) for hypercapnic failure (COPD) or cardiogenic edema when appropriate.
  • Intubate if worsening mental status, fatigue, hemodynamic instability, or inability to protect airway.

FAILURE CRITERIA

  • Rising CO2 with acidosis, persistent hypoxemia, exhaustion, shock.

ACTIVE SAFETY WARNINGS

  • NIV delays in failing patients increase mortality.
  • Over-oxygenation can worsen hypercapnia in CO2 retainers—target ranges.
  • Always treat the cause (PE, pneumonia, asthma, HF).