Guideline summary · Critical Care emergent
ARDS Ventilation: Low Tidal Volume + PEEP Strategy + Proning Triggers
Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.
Summary
For ARDS, prioritize lung-protective ventilation (low tidal volume, plateau pressure limits), appropriate PEEP, and early proning for severe hypoxemia. Avoid ventilator-induced lung injury through strict pressure targets.
Details
WHEN TO USE
- Acute hypoxemic respiratory failure meeting ARDS criteria (bilateral opacities, non-cardiogenic).
VENTILATOR TARGETS
- Tidal volume ~6 mL/kg predicted body weight.
- Keep plateau pressure <=30 cm H2O.
- Driving pressure minimization when feasible.
PEEP / OXYGENATION
- Use PEEP/FiO2 table strategy per protocol.
- Accept permissive hypercapnia if pH tolerated (protocol-based).
PRONING
- Consider early proning in moderate-severe ARDS with refractory hypoxemia despite optimization.
RESCUE THERAPIES
- Neuromuscular blockade, inhaled pulmonary vasodilators, ECMO referral per severity and center capability.
ACTIVE SAFETY WARNINGS
- Overventilation causes barotrauma and worsens mortality.
- Monitor hemodynamics with high PEEP.
- Proning requires airway security and pressure injury prevention.
Care settings
ICU
Source
ARDSNet lung-protective ventilation trials; SCCM critical care ventilation guidance; institutional ARDS protocols.
Topics
ARDSventilationlow_tidal_volumePEEPproning