Summary

Mechanical heart valves require lifelong warfarin with an INR target set by valve type and position; DOACs are contraindicated. Aortic mechanical valves target INR 2.5 (2.0-3.0) if no added risk, mitral and older-generation or multiple valves target 3.0 (2.5-3.5), often with low-dose aspirin. Peri-procedural management balances thrombotic vs bleeding risk and uses heparin bridging for high-risk valves.

Details

STANDARDIZED PROTOCOL

WHEN TO USE

  • Anticoagulation management for a patient with a MECHANICAL prosthetic heart valve (chronic management or around a procedure). Confirm valve TYPE, POSITION, and generation from the operative note — it drives the target.

CORE RULES

  • Warfarin is required; DOACs are CONTRAINDICATED for mechanical valves.
  • Bioprosthetic valves differ (usually not lifelong warfarin) — this protocol is for MECHANICAL valves.

INR TARGETS (VALVE- AND RISK-SPECIFIC)

  • Mechanical AORTIC valve, newer-generation, no additional risk factors: INR 2.5 (range 2.0-3.0).
  • Mechanical aortic with risk factors (AF, prior thromboembolism, LV dysfunction, hypercoagulable, older-generation valve): INR 3.0 (range 2.5-3.5).
  • Mechanical MITRAL valve (or any tilting-disk/ball-cage, or multiple mechanical valves): INR 3.0 (range 2.5-3.5).
  • ADD low-dose aspirin (e.g., 75-100 mg) in most patients unless bleeding risk precludes it.

PERI-PROCEDURE MANAGEMENT

  • Assess THROMBOTIC risk (valve type/position, AF, prior events) vs procedural BLEEDING risk.
  • High thrombotic risk (most mechanical mitral valves, older aortic valves, prior thromboembolism): BRIDGE with therapeutic heparin (IV unfractionated or LMWH) when warfarin is held.
  • Time warfarin interruption so INR is subtherapeutic only briefly; resume warfarin post-procedure and continue heparin until INR is therapeutic again.
  • Minor procedures (many dental/dermatologic) may not require interruption.

MONITORING

  • Regular INR; more frequent checks after any dose change, illness, or interacting medication.

ACTIVE SAFETY WARNINGS

  • NEVER use a DOAC for a mechanical valve.
  • Confirm valve type/position before setting the target — mitral and older valves need higher INR.
  • Do not leave a high-thrombotic-risk mechanical valve without bridging during warfarin interruption.

Care settings

ClinicInpatient

Source

ACC/AHA Guideline for the Management of Valvular Heart Disease; ACCP antithrombotic guidance