Insulin Pump/CGM Failure: Hyperglycemia + Ketone Gate (Avoid DKA)
Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.
Summary
Ketone-gated management for suspected insulin delivery failure: confirm BG, give correction by injection, recheck, and escalate to ED for moderate/high ketones or vomiting.
Details
WHAT THIS IS
- A rapid protocol for suspected insulin pump failure or CGM inaccuracy.
WHEN TO USE
- Pump user with unexpected hyperglycemia, infusion set/site issues, or symptoms of ketosis.
STEP 1 — CONFIRM
- Confirm CGM reading with fingerstick BG.
- Inspect pump: infusion site, tubing kinks, reservoir, occlusions, recent set change.
STEP 2 — KETONE GATE
- Check blood ketones (preferred) or urine ketones if BG high (commonly >250 mg/dL) or symptomatic.
LOW/NEGATIVE KETONES
- Give correction dose with rapid-acting insulin by injection (NOT via pump if delivery uncertain).
- Change infusion set and site (new set, new insulin).
- Recheck BG in 60–90 minutes.
- If BG not falling by expected amount per correction factor → treat as delivery failure; repeat injection correction per protocol and recheck.
MODERATE/HIGH KETONES OR VOMITING
- Treat as evolving DKA:
- Give rapid-acting insulin by injection (weight-based per clinic policy).
- Begin oral fluids if able.
- Go to ED now for labs (anion gap, bicarbonate), IV fluids, and insulin drip if indicated.
BACKUP BASAL PLAN (ESSENTIAL)
- If pump off >2 hours:
- Start long-acting basal insulin (glargine/detemir/degludec) at patient-specific backup dose (often ~80–100% of total daily basal from pump) per endocrinology plan.
ACTIVE SAFETY WARNINGS
- Pump failure can cause rapid DKA, especially in type 1 diabetes.
- Do not “stack” rapid-acting insulin without accounting for insulin-on-board.
Care settings
ClinicED
Source
ADA diabetes technology safety principles; DKA prevention protocols for insulin pump users.
Topics
insulin_pumpCGMketoneshyperglycemiaDKA_prevention