Summary

Oxygen escalation protocol with device selection by etiology and explicit failure criteria to trigger intubation early, preventing fatigue and arrest.

Details

INITIAL

  • Assess SpO2, work of breathing, mental status, hemodynamics.

ESCALATION

  • Low-flow nasal cannula.
  • HFNC:
  • Start flow and FiO2 per protocol; titrate to target SpO2.
  • NIV:
  • Use for COPD/hypercapnia or cardiogenic edema; selective use in hypoxemia per protocol.

FAILURE CRITERIA

  • Persistent hypoxemia despite escalation.
  • Rising work of breathing, fatigue.
  • Worsening mentation or inability to protect airway.
  • Hemodynamic instability.

INTUBATION

  • If failing: proceed to RSI with hemodynamic bundle.

ACTIVE SAFETY WARNINGS

  • Avoid prolonged NIV/HFNC struggle without improvement.
  • Aspiration risk with NIV in vomiting.

Care settings

EDICU

Source

ICU/ED oxygen escalation best practices; NIV success/failure criteria standards.

Topics

HFNCNIVintubationhypoxemiaescalation