Treatment protocol · Pulmonology & Critical Care emergent
Auto-PEEP in COPD: Hidden Cause of Ventilator Failure
Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.
Summary
Protocol to recognize and treat dynamic hyperinflation causing hypotension and dyssynchrony.
Details
WHEN TO USE
- COPD/asthma on ventilator with hypotension, high pressures, poor triggering
STEP 1 — SUSPECT AUTO-PEEP
- Expiratory flow not returning to baseline
- Rising plateau pressures or worsening hypotension after intubation
STEP 2 — IMMEDIATE VENT FIX
- Reduce RR
- Increase expiratory time (lower I:E)
- Reduce tidal volume as appropriate
STEP 3 — SUPPORT BP
- Fluids/pressors as needed; treat as obstructive shock physiology
STEP 4 — ACCEPT CO2
- Avoid aggressive ventilation that worsens trapping
SAFETY
- Watch for barotrauma
Care settings
ICU
Source
CHEST Mechanical Ventilation
Topics
COPDventilator