Treatment protocol · Pulmonology & Critical Care emergent

Auto-PEEP in COPD: Hidden Cause of Ventilator Failure

Source: CHEST Mechanical Ventilation

Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.

Summary

Protocol to recognize and treat dynamic hyperinflation causing hypotension and dyssynchrony.

Details

WHEN TO USE

  • COPD/asthma on ventilator with hypotension, high pressures, poor triggering

STEP 1 — SUSPECT AUTO-PEEP

  • Expiratory flow not returning to baseline
  • Rising plateau pressures or worsening hypotension after intubation

STEP 2 — IMMEDIATE VENT FIX

  • Reduce RR
  • Increase expiratory time (lower I:E)
  • Reduce tidal volume as appropriate

STEP 3 — SUPPORT BP

  • Fluids/pressors as needed; treat as obstructive shock physiology

STEP 4 — ACCEPT CO2

  • Avoid aggressive ventilation that worsens trapping

SAFETY

  • Watch for barotrauma