Treatment protocol · Infection Control urgent

Aerosol-Generating Procedures: Room + PPE Requirements Quick Rules (ED/ICU)

Last updated

Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.

Summary

Use appropriate room (AIIR when needed), N95/PAPR + eye protection + gown/gloves, limit personnel, and follow room clearance times to prevent exposures during AGPs.

Details

AGP TRIGGERS

  • Intubation/extubation, NIV, bronchoscopy, open suctioning, nebulized therapy in high-risk pathogen.

ROOM

  • AIIR/negative pressure when indicated; door closed.

PPE

  • N95 with seal check (or PAPR) + eye protection + gown + gloves.

PROCESS

  • Limit room personnel.
  • Use viral filters where appropriate.
  • Follow post-AGP air exchange clearance time before unprotected entry.

DOFFING

  • Doff carefully with hand hygiene at each step; observer for high-risk.

ACTIVE SAFETY WARNINGS

  • Fit-testing required; poor seal defeats N95.
  • Doffing is highest exposure moment.

Care settings

EDICU

Source

CDC airborne/respiratory protection principles; ED/ICU AGP workflow standards.

Topics

AGPN95negative_pressureintubationPPE