Treatment protocol · Infection Control urgent
Aerosol-Generating Procedures: Room + PPE Requirements Quick Rules (ED/ICU)
Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.
Summary
Use appropriate room (AIIR when needed), N95/PAPR + eye protection + gown/gloves, limit personnel, and follow room clearance times to prevent exposures during AGPs.
Details
AGP TRIGGERS
- Intubation/extubation, NIV, bronchoscopy, open suctioning, nebulized therapy in high-risk pathogen.
ROOM
- AIIR/negative pressure when indicated; door closed.
PPE
- N95 with seal check (or PAPR) + eye protection + gown + gloves.
PROCESS
- Limit room personnel.
- Use viral filters where appropriate.
- Follow post-AGP air exchange clearance time before unprotected entry.
DOFFING
- Doff carefully with hand hygiene at each step; observer for high-risk.
ACTIVE SAFETY WARNINGS
- Fit-testing required; poor seal defeats N95.
- Doffing is highest exposure moment.
Care settings
EDICU
Source
CDC airborne/respiratory protection principles; ED/ICU AGP workflow standards.
Topics
AGPN95negative_pressureintubationPPE