Summary

Stepwise oxygen escalation with explicit failure gates for early intubation to prevent crash airway and arrest.

Details

WHEN TO USE

  • SpO2 <90% (or below target) despite supplemental oxygen and increased work of breathing.

STEP 1: STANDARD OXYGEN

  • Nasal cannula → nonrebreather. Target SpO2 typically 92–96% (88–92% if chronic CO2 retention/COPD per protocol).

STEP 2: HFNC

  • Start HFNC (e.g., 40–60 L/min) + titrate FiO2.
  • Reassess at 15–30 min: RR, WOB, SpO2, mentation.

STEP 3: NIV (SELECTIVE)

  • Best for COPD hypercapnia or cardiogenic pulmonary edema.
  • If trialing NIV in hypoxemia: reassess within 30–60 min.

INTUBATION FAILURE GATES (DO NOT DELAY)

  • Persistent SpO2 below goal despite maximal noninvasive support.
  • Rising WOB/fatigue, diaphoresis, accessory muscle exhaustion.
  • Altered mental status, inability to protect airway.
  • Hemodynamic instability/pressors escalating.

POST-INTUBATION

  • Lung-protective ventilation; consider ARDS pathway if PaO2/FiO2 low.

ACTIVE SAFETY WARNINGS

  • Prolonged “struggle” on NIV/HFNC increases mortality.
  • Sedatives can precipitate apnea—airway-ready setup required.