Guideline summary · Pulmonology & Critical Care urgent

PEEP Titration: Avoiding Overdistension and Hypotension

Source: ATS Mechanical Ventilation · Last updated

Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.

Summary

Excess PEEP causes overdistension, worsens right ventricular failure, and reduces cardiac output. Titrate to the lowest PEEP that achieves target oxygenation; monitor plateau pressure and hemodynamics closely.

Details

CLUES OF OVERPEEP

  • Rising plateau pressure
  • Worsening BP

STRATEGY

  • Use lowest PEEP achieving oxygenation.

Care settings

ICU

Source

ATS Mechanical Ventilation

Topics

PEEPventilation

Get the DUK-C app