Guideline summary · Endocrinology emergent

Insulin Pump/CGM Failure: Hyperglycemia + Ketone Gate (Avoid DKA)

Last updated

Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.

Summary

Pump failure can cause rapid insulin deficiency. Use a ketone-driven protocol: check ketones early, give rapid-acting insulin by injection, and escalate to ED if ketones high or vomiting.

Details

WHEN TO USE

  • Insulin pump malfunction, infusion site failure, or CGM/sensor failure resulting in unexpected hyperglycemia in a patient with type 1 diabetes (or insulin-dependent type 2) on pump therapy.

KETONE GATE — CHECK IMMEDIATELY

  • Any unexplained hyperglycemia (e.g., glucose >250 mg/dL) in a pump user should prompt IMMEDIATE blood or urine ketone checking — pump failure can rapidly progress to DKA given the very short duration of action of rapid-acting insulin used in pumps (no long-acting "reservoir" of insulin on board as with injection-based basal regimens).
  • Blood beta-hydroxybutyrate is preferred over urine ketones when available (more sensitive, real-time reflection of current ketosis).

IMMEDIATE ACTIONS — DO NOT SIMPLY BOLUS THROUGH THE PUMP

  • Suspected pump/site failure with hyperglycemia and ketones present: give a correction dose by INJECTION (insulin pen or syringe), NOT through the potentially malfunctioning pump — assume the pump/infusion site is unreliable until proven otherwise.
  • Replace the infusion set/site entirely (not just troubleshoot the existing one) if pump delivery is suspected as the cause.
  • Encourage oral hydration; recheck glucose and ketones within 1-2 hours after the injected correction dose.

ESCALATION TO DKA PATHWAY

  • Significant ketosis (moderate-large) with hyperglycemia, nausea/vomiting, abdominal pain, or any acidosis on basic metabolic panel -> manage per full DKA protocol (IV fluids, IV insulin infusion, electrolyte monitoring) — do not attempt to manage established DKA with subcutaneous correction doses alone.

ACTIVE SAFETY WARNINGS

  • Pump users can progress to DKA much faster than patients on injected basal-bolus regimens, because there is no depot of long-acting insulin to fall back on if delivery is interrupted — treat any unexplained hyperglycemia in a pump user as a potential pump failure until proven otherwise.
  • Do not simply increase the pump basal/bolus settings without first confirming the pump/site is functioning correctly — this can delay recognition of true mechanical failure.

Care settings

ClinicED

Source

ADA Standards of Care; Diabetes Technology Society Guidance on Pump/CGM Failure Management

Topics

insulin_pumpCGMketoneshyperglycemiaDKA_prevention

Get the DUK-C app