Guideline summary · Otolaryngology emergent

Foreign Body in Nose/Ear: Removal Techniques + Button Battery Emergency Protocol

Last updated

Educational reference for clinicians. Not a substitute for clinical judgment or the full source guideline.

Summary

ENT foreign bodies are common but button batteries and magnets are emergencies. Use a risk-based removal approach and escalate immediately for batteries, caustic objects, or unsuccessful attempts.

Details

WHEN TO USE

  • Suspected FB in ear or nose.

EMERGENT OBJECTS

  • Button battery: remove immediately.
  • Paired magnets: urgent removal.

REMOVAL PRINCIPLES

  • Good visualization and immobilization.
  • Limit attempts to avoid trauma.
  • Use appropriate tools: curette, suction, forceps; irrigation only when safe (no battery/perf suspicion).

ACTIVE SAFETY WARNINGS

  • Button battery causes liquefaction necrosis within hours.
  • Repeated attempts worsen bleeding/swelling.

Care settings

EDClinic

Source

Pediatric ENT foreign body management standards; button battery emergency guidance.

Topics

foreign_bodybutton_batterymagnetsremovalENT_emergency

Get the DUK-C app