Summary
ENT foreign bodies are common but button batteries and magnets are emergencies. Use a risk-based removal approach and escalate immediately for batteries, caustic objects, or unsuccessful attempts.
Details
WHEN TO USE
- Suspected FB in ear or nose.
EMERGENT OBJECTS
- Button battery: remove immediately.
- Paired magnets: urgent removal.
REMOVAL PRINCIPLES
- Good visualization and immobilization.
- Limit attempts to avoid trauma.
- Use appropriate tools: curette, suction, forceps; irrigation only when safe (no battery/perf suspicion).
ACTIVE SAFETY WARNINGS
- Button battery causes liquefaction necrosis within hours.
- Repeated attempts worsen bleeding/swelling.
Care settings
EDClinic
Source
Pediatric ENT foreign body management standards; button battery emergency guidance.